Welcome to Karmat Alfikr Trading Est.

BELPYCNO L

BELPYCNO L is a fully automated gas pycnometer for the determination of volume and skeleton density of powders, granulates, porous materials, mixtures, pastes, and liquids. The combination of an internal temperature control and an absolute pressure transducer compensates any influences from ambient temperature and pressure fluctuations.

The gas pycnometer replaces the classical method of liquid displacement, utilizing a probing gas such as Helium which can reach even the smallest pores with less than one nanometer in diameter. Thus, the density of powders and porous materials can be determined exactly.

The gas pycnometer works as a standalone instrument or by connecting it to a computer. The included software is easy to use and offers full control and a wide array of functions, from programming the computer to the report and storage of analytical data and results. Additionally, the computed volume and density are displayed in-situ for each measurement step.


Gas pycnometer BELPYCNO L


  • Built-in linearized absolute pressure transducer
  • Sample cell and reference volumes are separated from the electronics
  • Built-in accurate ATC (Automatic Temperature Control)
  • Short measurement time and fast system stabilization
  • Unrivalled reproducibility of results

Gas pycnometer BELPYCNO L Accurate Density Determination for Various Applications


The BELPYCNO L gas pycnometer is equipped with up to 3 reference chamber volumes (20, 40 and 60 cm3) in order to give the best performance in combination with the chosen sample chamber (ca. 4, 20, 40, 60, 100 and 150 cm3). Independent of ambient temperature and pressure variations, the pycnometer allows density measurements which are not limited by time consuming calibration procedures.

Once calibrated the gas pycnometer carries out the analysis without any concerns. No contamination risks due to gas loading from reference chamber (high pressure) into sample chamber (low pressure), supported by programmable discharge restriction and easy use of paper filters. Variable loading pressure permits the analysis of foams and compressible samples.

The gas pycnometer BELPYCNO L is suitable for the density measurement of a wide range of applications: powders, wood, building materials, catalysts, liquids, and pastes, activated carbon, food, pharmaceuticals, ... and many others!

Gas pycnometer BELPYCNO L Technical Data



Reference chamber volumes Approx. 20 cm³, 40 cm³ and 60 cm³
Sample chamber volumes Approx. 4 cm³, 20 cm³, 40 cm³, 60 cm³, 100 cm³ and 150 cm³
Probe gas Helium (other inert gases possible)
Control Integrated micro processor
Keyboard Alphanumeric foil
Display 4-line 40 characters LCD-display with back light
Pre-treatment Flow, programmable purge cycles optional with vacuum preparation
Temperature 14° C to 40° C (optional 60° C with external oven) resolution: ± 0.01° C
Pressure transducer 0.001 kPa displayed resolution
AD-Converter 19 Bit
Accuracy 0.01 %
Reproducibility 0.01 %
Vacuum connector KF-10
Interfaces 2 x serial (ext. balance, PC-data transfer) 1x parallel (printer)
Sensor (optional) Humidity
CE certified yes


BELPYCNO

The BELPYCNO is an analyzer for quick and reliable measurement of the true density of solid materials and powders using by gas displacement.


The BELPYCNO offers high-resolution pressure measurement, variable cell volumes, greaseless, and one-touch sample cell cap. These features ensure high accuracy of the measurement result and easy operation.


  • Highly precise measurement of the sample volumes thanks to variable cell volumes
  • Sample cell cap without grease
  • Convenient one-hand operation via touch screen

Options


  • Label printer for result output
  • Sample weight acquisition from electronic balance
  • Thermostatic water bath to maintain the sample temperature

Technical Data


Measurement principle Gas displacement method
Sample cell volume 10 cm3, 3.5 cm3, 1 cm3
Measurement accuracy 0.03% of F.S. +0.03% of reading
Repeatability 0.02% of F.S.
Pretreatment Gas purge, flow, vacuum (option)
Pretreatment pressure 0-145kPa (Gauge)
Applicable gas He, N2, inert gas
Measurement pressure 145kPa (Gauge)
Repetition times of measurement Maximum 100 times)
Mean number of measurements Maximum 10 times
Measurement temperature range 15-35°C, water bath: 15-50°C (option)
Calibration method Automatic calibration with calibration sphere
Interface Input: RS232C (communication with printer) Output: RS232C (communication with electric balance)
Dimensions (W x H x D) 270 x 170 x 300 mm
Weight 8 kg
Utility – Gas, Joint, Power He, N2, inert gases: 150kPa (G); 1/8" Swagelok connection; AC100~120V/200-240 V / 200 W, 50 / 60 Hz
CE certified Yes